SHURE MX183
Omnidirectional Lavalier Microphone
Omnidirectional lavalier microphone offers an interchangeable condenser cartridge and consists of a windscreen and a dual tie clip for 2 microphones. It features wide dynamic range and frequency response for accurate and balanced sound reproduction.
8,424,000đ
Viewed738 times
What is the MX183 best suited to?
The MX183 omnidirectional miniature lavalier condenser microphone is designed for use in speech applications such as broadcast presenting, speeches, lectures and for use in houses of worship.
What is an interchangeable cartridge?
All the Microflex series of microphones use interchangeable cartridges (sold separately) which means you can swap between cardioid, supercardioid and omnidirectional condenser cartridges simply by screwing them on to the top of the lavalier mic.

Want to go wireless?
The MX183 is designed for wired use and includes an in-line preamplifier and a 1.2m cable with TA4F connector. If you wish to go wireless, choose the WL183 which is the same microphone but without the pre-amplifier and connects directly into any Shure wireless bodypack.

FEATURES
- Wide dynamic range and frequency response for accurate sound reproduction across the audio spectrum
- Interchangeable cartridges that provide an optimal choice for each application
- Rotatable tie-clip that pivots in 90 degree increments for placement flexibility
- Supplied snap-fit foam windscreen that controls breath noise and stays on securely
- Balanced, transformerless output for increased immunity to noise over long cable runs
- Supplied dual tie clip holds two microphones for dual miking applications
- Type: Electret Condenser
- Frequency Response: 50–17000 Hz
- Polar Pattern
|
MX183 |
Omnidirectional |
|
MX185 |
Cardioid |
|
MX184 |
Supercardioid |
- Output Impedance: 180 Ω
- Output Configuration: Active Balanced
- Sensitivity (@ 1 kHz, open circuit voltage)
|
Cardioid |
–35 dBV/Pa(18 mV) |
|
Supercardioid |
–34 dBV/Pa(21 mV) |
|
Omnidirectional |
–28 dBV/Pa(42 mV) |
- Maximum SPL (1 kHz at 1% THD, 1 kΩ load)
|
Cardioid |
124 dB |
|
Supercardioid |
123 dB |
|
Omnidirectional |
117 dB |
- Self Noise (A-weighted)
|
Cardioid |
28 dB SPL |
|
Supercardioid |
27 dB |
|
Omnidirectional |
21 dB SPL |
- Signal-to-Noise Ratio (Ref. 94 dB SPL at 1 kHz)
|
Cardioid |
66 dB |
|
Supercardioid |
68 dB |
|
Omnidirectional |
74 dB |
- Dynamic Range (1 kΩ load, @ 1 kHz): 96 dB
- Common Mode Rejection (10 Hz to 100 kHz): 45 dB, minimum
- Clipping Level at 1% THD: –6 dBV (0.5 V)
- Polarity: Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output XLR connector
- Environmental Conditions
|
Operating Temperature |
–18–57°C (0–135°F) |
|
Storage Temperature |
–29–74°C (–20–165°F) |
|
Relative Humidity |
0–95% |
- Power Requirements: 11–52 V DC, 2.0 mA
- Cable: 1.2 m (4 ft)