SHURE TL47

SHURE TL47

TwinPlex TL47 Subminiature Lavalier Microphone
The expressively natural sounding TwinPlex™ TL47 is available with connector options for most bodypack transmitters, color options that meet numerous situational needs, and mounting choices for all professional applications. The low sensitivity can handle the most critical acoustic environments without distortion, and the 1.6 mm paintable cable stands up to the most demanding use. With extensive solutions for any application, it’s the go-to line for flexibility.
Brand:
Product Code:TL47C/O-MTQG-A
  • With a variety of colors and connectors, the TL47 is ideal for nearly any application
  • Twice the surface area of other subminiature microphones for pristine, natural response and robust low-frequency response due to the patent pending dual-diaphragm design
  • Improved off-axis consistency yields accurate reproduction regardless of vocal source position or movement
  • Best-in-class low self-noise and dynamic range for cleaner audio production
  • Interchangeable sweat- and moisture-resistant frequency caps prevent sweat-outs due to an invisible syperhydrophobic nanoscopic coating
  • Paintable 1.6 mm cable that is immune to memory effect and kinks
  • Dual redundant ground in cable serves as secondary shield for longevity
  • Sound signature: Natural
  • Sensitivity: Low
  • Colors: White, Tan, Cocoa, Black
  • Connectors: LEMO, MTQG/TA4F, MicroDot, XLR/Preamp, NC (bare wire)
  • Accessories: Available with or without accessories

Micro cài áo Shure TL47 và bodypack ADX1M

In dialogue or monologue. Song or speech. A single word can affect the whole story. Through sweat, noise, and wear and tear, your little lavalier has an enormous job to do. Shure TwinPlex stands up to the toughest conditions to make every word a clear statement of quality. Natural audio at high or low frequency, the innovative dual-diaphragm captures the complete weight of your voice. And the capsule design maximizes effective surface area in an easy-to-conceal package. So sound suits performer, not the other way around.

diễn viên dùng micro lavalier trên sân khấu

No more “sweat-outs.” The superhydrophobic coating keeps perspiration from upstaging the sound. And the medical-grade cable technology flexes to fit the costume design and the demanding schedule. So your lavalier rises to the challenge, night after night.

Micro cài áo Shure TL47 và bodypack mini ADX1M

The TwinPlex™ TL47 is available with connector options for most bodypack transmitters, color options that meet numerous situational needs, and mounting choices for all professional applications. The low sensitivity can handle the most critical acoustic environments without distortion, and the 1.6 mm paintable cable stands up to the most demanding use. With extensive solutions for any application, it’s the go-to line for flexibility.


Find An Answer

How to Choose the Best Lavalier Microphone
Shure Lavalier / Headset compatibility with Wireless Systems
TwinPlex: Takes the Stage

All specification values are based on using a typical bodypack with 5 V bias input or the RPM400MTQG preamplifier. When using the RPM400LEMO amplifier, refer to the RPM400LEMO specifications. [1]

  • Microphone Capsule: Dual-Diaphragm, Prepolarized Condenser
  • Polar Pattern: Omnidirectional
  • Frequency Response: 20 Hz to 20 kHz
  • Sensitivity

 

 

TL46

-37.0 dBV(14.1 mV)at 1 kHz [2]

TL45, TL47, TL48

-45.0 dBV(5.62 mV)at 1 kHz [2]

  • Self-Noise, A-Weighted, Equivalent Acoustical

 

 

TL46

24.0 dB SPL-A

TL45, TL47, TL48

24.5 dB SPL-A

  • Signal-To-Noise Ratio [3]

 

 

TL46

70.0 dB

TL45, TL47, TL48

69.5 dB

  • Output Clipping Level: 3.0 dBV,1 kHz at 1% THD, typical
  • Maximum SPL [4]

 

 

TL46

134.0 dB SPL,1 kHz at 1% THD, typical

TL45, TL47, TL48

142.0 dB SPL,1 kHz at 1% THD, typical

  • Dynamic Range

 

 

TL46

110.0 dB typical

TL45,TL47, TL48

117.5 dB typical

  • Microphone Current Draw: 120 to 240 µA, typical
  • Bias Voltage (Recommended Operating Voltage): 5 V DC
  • Housing: Molded ABS
  • Polarity

 

 

MTQG, XLR connector

Positive pressure on diaphragm produces positive voltage on pin 3 with respect to pin 1

LEMO, NC, MDOT

Positive pressure on diaphragm produces negative voltage on pin 3 with respect to pin 1.

  • Cable Diameter

 

 

TL45

1.1 mm

TL46, TL47, TL48

1.6 mm

  • Cable Length

 

 

MTQG, LEMO, MDOT

66 in. (1.67 m)

NC, XLR connector

96 in. (2.43 m)

  • Net Weight (with cable): 12.0 g (0.42 oz.)

[1]All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with slightly decreased headroom and sensitivity.

[2]1 Pa=94 dB SPL

[3]S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise, A-weighted

[4]THD of microphone preamplifier when applied input signal level is equivalent to cartridge output at specified SPL

  • Dimensions
  A B C D
  Cable Length Cable Diameter Microphone Length Microphone Diameter
TL45 66 in. (1.67M) 1.1MM 13.5MM 5.6MM
TL46 66 in. (1.67M) 1.6MM 13.5MM 5.6MM
TL47-MTQG, TL47-MDOT, TL47-LEMO 66 in. (1.67M) 1.6MM 13.5MM 5.6MM
TL47-XLR, TL47-NC 96 in. (2.43M) 1.6MM 13.5MM 5.6MM
TL48-MTQG, TL48-MDOT, TL48-LEMO 66 in. (1.67M) 1.6MM 19MM 5.3MM
TL48-XLR, TL48-NC 96 in. (2.43M) 1.6MM 19MM 5.3MM